AstroStart Security System VSS-113 Guía de instalación Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 18
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
Primary Harness (H1) Wire Connection Guide
This guide describes in detail the connection of each wire. Also included are possible applications of each wire. This
system was designed with the ultimate in flexibility and security in mind. Many of the wires have more than one possible
function. Please read carefully to ensure a thorough understanding of this unit.
H1/1 ----- PINK (-) 200mA CHANNEL 2 VALIDITY OUTPUT
H1/2 ----- RED (+) CONSTANT POWER INPUT
H1/3 ----- RED/WHITE (+) SIREN OUTPUT
H1/4 ----- ORANGE (+) SWITCHED IGNITION INPUT, ZONE 5
H1/5 ----- BLACK (-) CHASSIS GROUND INPUT
H1/6 ----- PURPLE (+) DOOR TRIGGER INPUT, ZONE 3
H1/7 ----- BLACK/WHITE (-) INSTANT TRIGGER INPUT, ZONE 1
H1/8 ----- WHITE (-) DOOR TRIGGER INPUT, ZONE 3
H1/9 ----- GREY (-) 200mA DOME-LIGHT SUPERVISION OUTPUT
H1/10 ----- PINK/WHITE (-) 200mA CHANNEL 3 PROGRAMMABLE OUTPUT
H1/11 ----- GREEN (+ / -) SELECTABLE LIGHT FLASH OUTPUT
H1/12 ----- ORANGE/BLACK (-) 500mA GROUND-WHEN-ARMED OUTPUT
H1/1 PINK (-) 200 mA Channel 2 Output
H1/1 PINK
(+) 12V IF (+) SWITCHED
© 2006 Astroflex Electronics. – All rights reserved 2
When the system receives the code controlling
channel 2 for longer than 1.5 seconds, the PINK
wire will supply an output as long as the
transmission continues.
This is often used to operate a trunk/hatch release
or other relay/driven function.
(-) GROUND IF (-) SWITCHED
NEVER USE this wire to drive anything but a relay or a low-current input!
The transistorized output can only supply 200 mA of current. Connecting
directly to a solenoid, motor, or other high-current device will cause it to fail.
H1/2 RED (+) Constant Power Input
Connect to the battery positive terminal or the constant 12V supply to the ignition switch.
Always use a fuse within 12 inches of the point you obtain
(+)12V. Do not use the 15 amp fuse in the harness for this
purpose. This fuse protects the module itself.
H1/3 RED/WHITE (+) Siren Output
Connect this to the RED wire of the siren. Connect the BLACK wire of the siren
to (-) chassis ground, preferably at the same point you connect the control
module’s BLACK ground wire.
H1/3 RED/WHITE
(+) SIREN OUTPUT
RED
BLACK
SWITCHED TRUNK
RELEASE WIRE
+12V CONSTANT FUSED
Vista de pagina 3
1 2 3 4 5 6 7 8 9 ... 17 18

Comentarios a estos manuales

Sin comentarios