MENU #2 - ADVANCED FEATURES
2-1 SIREN/HORN HONK: The system can be programmed to output pulses instead of a continuous output when the
system is triggered. This is useful to honk the factory horn in applications where a siren is undesirable. Remember that
the unit is only capable of supplying 1 amp of current. A relay will be required to interface with most factory horn
systems.
2-2 SIREN DURATION 30/60 SECONDS: It is possible to program the unit to sound for 30 or 60 seconds
during the triggered sequence. Some states have laws regulating how long a security system can sound.
When using the programming tool, the siren can be programmed to sound for any length of time ranging from
1 to 180 seconds. Using the SELECT button of the programming tool will adjust the siren duration in one second
increments.
2-3 NUISANCE PREVENTION® CIRCUITRY (NPC®) ON/OFF: NPC® stops repeated triggering of the same zone. If
one zone is triggered three times in one hour, that zone is bypassed for one hour, starting from the time of the third
trigger. During that hour, if the system detects a trigger on that zone again, the system resets the one hour timer. If one
hour passes and the zone has not triggered again, the zone is activated and can trigger the system again. If NPC® is
turned off, the system will respond to repeated triggers on the sensor inputs and will do so indefinitely. Some states
have laws regulating how many times a security system can trigger before it is considered a nuisance and the vehicle is
towed away. Refer to the owner’s manual for additional details.
2-4 PROGRESSIVE DOOR TRIGGER ON/OFF: The system responds to a door trigger input with a progressive
response. When the door is opened with the system armed, the siren will chirp 10 times prior to the full triggered
sequence. The door trigger is still treated as an instant trigger and closing the door quickly will not prevent a full
triggered sequence from occurring. If the progressive door trigger is programmed off, the full siren output will occur the
moment the door is opened.
2-5 VALET PULSE COUNT ONE TO FIVE PULSES: The system can be programmed to count the number presses of
the valet button before disarming the security system or VRS®. The factory default setting is one pulse. The unit can be
set for two to five pulses using the two-chirp setting to select the pulse count.
Ghost Switch Option: For added security, the GREY wire on the two-pin Valet/Program can be connected to any switch
in the vehicle that provides a positive (+) momentary pulse.
2-6 BYPASS NOTIFICATION ON/OFF: when programmed on, any active zone input to the system during arming will
generate a bypass notification chirp. When programmed OFF, no bypass notification chirps will be generated if any
zone is active during arming.
2-7 IGNITION-CONTROLLED DOME-LIGHT SUPERVISION ON/OFF: If turned on, the system will turn on the DOME-
LIGHT for 30 seconds when the ignition is turned off. The optional DOME-LIGHT supervision feature must be installed.
2-8 DOUBLE PULSE UNLOCK ON/OFF: Some vehicles require two pulses on a single wire to unlock the doors. When
the double pulse unlock feature is turned on, the BLUE H2/A wire will supply two negative pulses instead of a single
pulse. At the same time, the BROWN H2/C wire will supply two positive pulses instead of a single pulse. This makes it
possible to directly interface with double pulse vehicles without any extra parts.
2-9 DOUBLE PULSE LOCK: Some vehicles require two pulses on a single wire to lock the doors. When the double
pulse lock feature is turned on, the BROWN H2/C wire will supply two negative pulses instead of a single pulse. At the
same time, the BLUE H2/A wire will supply two positive pulses instead of a single pulse. This makes it possible to
directly interface with double pulse vehicles without any extra parts.
2-10 CHANNEL 3 VALIDITY/LATCHED/LATCHED RESET WITH IGNITION/30 SECOND TIMED/SECOND UNLOCK
OUTPUT: Channel 3 can be programmed for these output configurations. The unit is set to the default validity output.
To change the configuration, use the two-chirp setting to toggle to the different configurations.
2-11 COMFORT CLOSURE: The system can be programmed to close the windows when the system is armed. A
20-second output starts 200mS after the last lock
pulse. The Comfort Closure output will be cancelled if the unlock
button is pressed. If programmed, the lock output wire will provide this function.
Comfort Closure is deleted if one-time bypass is activated.